furnace/doc/7-systems/ym2612.md

68 lines
2.2 KiB
Markdown
Raw Normal View History

2022-01-16 06:10:43 +00:00
# Yamaha YM2612
2022-03-26 18:55:20 +00:00
one of two chips that powered the Sega Genesis. It is a six-channel, four-operator FM synthesizer. Channel #6 can be turned into 8-bit PCM player.
2022-01-16 06:10:43 +00:00
# effects
- `10xy`: set LFO parameters.
- `x` toggles the LFO.
- `y` sets its speed.
- `11xx`: set feedback of channel.
- `12xx`: set operator 1 level.
- `13xx`: set operator 2 level.
- `14xx`: set operator 3 level.
- `15xx`: set operator 4 level.
- `16xy`: set multiplier of operator.
- `x` is the operator (1-4).
2023-05-20 22:21:51 +00:00
- `y` is the multiplier.
2022-01-16 06:10:43 +00:00
- `17xx`: enable PCM channel.
- this only works on channel 6.
- `18xx`: toggle extended channel 3 mode.
- 0 disables it and 1 enables it.
2022-10-16 05:53:05 +00:00
- only in extended channel 3 chip.
2022-01-16 06:10:43 +00:00
- `19xx`: set attack of all operators.
- `1Axx`: set attack of operator 1.
- `1Bxx`: set attack of operator 2.
- `1Cxx`: set attack of operator 3.
- `1Dxx`: set attack of operator 4.
- `30xx`: enable envelope hard reset.
- this works by inserting a quick release and tiny delay before a new note.
- `50xy`: set AM of operator.
- `x` is the operator (1-4). a value of 0 means "all operators".
- `y` determines whether AM is on.
- `51xy` set SL of operator.
- `x` is the operator (1-4). a value of 0 means "all operators".
- `y` is the value.
- `52xy` set RR of operator.
- `x` is the operator (1-4). a value of 0 means "all operators".
- `y` is the value.
- `53xy` set DT of operator.
- `x` is the operator (1-4). a value of 0 means "all operators".
- `y` is the value:
2022-05-04 22:39:22 +00:00
- 0: -3
- 1: -2
- 2: -1
- 3: 0
- 4: 1
- 5: 2
- 6: 3
- 7: -0
- `54xy` set RS of operator.
- `x` is the operator (1-4). a value of 0 means "all operators".
- `y` is the value.
- `55xy` set SSG-EG of operator.
- `x` is the operator (1-4). a value of 0 means "all operators".
- `y` is the value (0-8).
- values between 0 and 7 set SSG-EG.
- value 8 disables it.
- `56xx`: set DR of all operators.
- `57xx`: set DR of operator 1.
- `58xx`: set DR of operator 2.
- `59xx`: set DR of operator 3.
- `5Axx`: set DR of operator 4.
- `5Bxx`: set D2R/SR of all operators.
- `5Cxx`: set D2R/SR of operator 1.
- `5Dxx`: set D2R/SR of operator 2.
- `5Exx`: set D2R/SR of operator 3.