the OPL synthesizers are nominally two-operator (OPL3 supports 4-operator mode on up to six channels), meaning it takes two oscillators to produce a single sound.
- **Sustain flag (SUS)**: when enabled, the envelope pauses ("sustains") once it reaches the Sustain Level and does not proceed to the release phase until note off.
- **Attack Rate (AR)**: determines the rising time for the sound. the bigger the value, the faster the attack (0 to 15).
- **Decay Rate (DR)**: determines the diminishing time for the sound. the higher the value, the shorter the decay. it's the initial amplitude decay rate (0 to 15).
- **Sustain Level (SL)**: determines the point at which the sound ceases to decay and changes to a sound having a constant level. the sustain level is expressed as a fraction of the maximum level (0 to 15).
- **Release Rate (RR)**: determines the rate at which the sound disappears after note off. the higher the value, the shorter the release (0 to 15).
- **Total Level (TL)**: represents the envelope’s highest amplitude, with 0 being the largest and 63 (decimal) the smallest. a change of one unit is about 0.75 dB.
- **Frequency Multiplier (MULT)**: sets the coarse pitch offset in relation to the note (0 to 15). 0 is -1 octave, 1 is 0 octaves, 2 is 1 octave, 3 is 1 octave 7 semitones, and so on.
- note that values 11, 13 and 14 behave as 10, 12 and 12 respectively.