mirror of
https://github.com/ryujinx-mirror/ryujinx.git
synced 2024-12-03 07:17:25 +00:00
08831eecf7
* IPC refactor part 3 + 4: New server HIPC message processor with source generator based serialization * Make types match on calls to AlignUp/AlignDown * Formatting * Address some PR feedback * Move BitfieldExtensions to Ryujinx.Common.Utilities and consolidate implementations * Rename Reader/Writer to SpanReader/SpanWriter and move to Ryujinx.Common.Memory * Implement EventType * Address more PR feedback * Log request processing errors since they are not normal * Rename waitable to multiwait and add missing lock * PR feedback * Ac_K PR feedback
77 lines
No EOL
2.7 KiB
C#
77 lines
No EOL
2.7 KiB
C#
using Ryujinx.Common.Logging;
|
|
using Ryujinx.HLE.HOS.Ipc;
|
|
using Ryujinx.HLE.HOS.Kernel.Threading;
|
|
using Ryujinx.Horizon.Common;
|
|
using System;
|
|
|
|
namespace Ryujinx.HLE.HOS.Services.Nim.Ntc.StaticService
|
|
{
|
|
class IEnsureNetworkClockAvailabilityService : IpcService
|
|
{
|
|
private KEvent _finishNotificationEvent;
|
|
private ResultCode _taskResultCode;
|
|
|
|
public IEnsureNetworkClockAvailabilityService(ServiceCtx context)
|
|
{
|
|
_finishNotificationEvent = new KEvent(context.Device.System.KernelContext);
|
|
_taskResultCode = ResultCode.Success;
|
|
|
|
// NOTE: The service starts a thread that polls Nintendo NTP server and syncs the time with it.
|
|
// Additionnally it gets and uses some settings too:
|
|
// autonomic_correction_interval_seconds, autonomic_correction_failed_retry_interval_seconds,
|
|
// autonomic_correction_immediate_try_count_max, autonomic_correction_immediate_try_interval_milliseconds
|
|
}
|
|
|
|
[CommandHipc(0)]
|
|
// StartTask()
|
|
public ResultCode StartTask(ServiceCtx context)
|
|
{
|
|
if (!context.Device.Configuration.EnableInternetAccess)
|
|
{
|
|
return (ResultCode)Time.ResultCode.NetworkTimeNotAvailable;
|
|
}
|
|
|
|
// NOTE: Since we don't support the Nintendo NTP server, we can signal the event now to confirm the update task is done.
|
|
_finishNotificationEvent.ReadableEvent.Signal();
|
|
|
|
Logger.Stub?.PrintStub(LogClass.ServiceNtc);
|
|
|
|
return ResultCode.Success;
|
|
}
|
|
|
|
[CommandHipc(1)]
|
|
// GetFinishNotificationEvent() -> handle<copy>
|
|
public ResultCode GetFinishNotificationEvent(ServiceCtx context)
|
|
{
|
|
if (context.Process.HandleTable.GenerateHandle(_finishNotificationEvent.ReadableEvent, out int finishNotificationEventHandle) != Result.Success)
|
|
{
|
|
throw new InvalidOperationException("Out of handles!");
|
|
}
|
|
|
|
context.Response.HandleDesc = IpcHandleDesc.MakeCopy(finishNotificationEventHandle);
|
|
|
|
return ResultCode.Success;
|
|
}
|
|
|
|
[CommandHipc(2)]
|
|
// GetResult()
|
|
public ResultCode GetResult(ServiceCtx context)
|
|
{
|
|
return _taskResultCode;
|
|
}
|
|
|
|
[CommandHipc(3)]
|
|
// Cancel()
|
|
public ResultCode Cancel(ServiceCtx context)
|
|
{
|
|
// NOTE: The update task should be canceled here.
|
|
_finishNotificationEvent.ReadableEvent.Signal();
|
|
|
|
_taskResultCode = (ResultCode)Time.ResultCode.NetworkTimeTaskCanceled;
|
|
|
|
Logger.Stub?.PrintStub(LogClass.ServiceNtc);
|
|
|
|
return ResultCode.Success;
|
|
}
|
|
}
|
|
} |